Cladding Panels

Cembrit Solid

Cembrit Solid is a range of 18 intense colours with matching surface and base board colour.

Cladding Panels

Cembrit Solid

Colours & Measures

Cembrit Solid

Selected colour: S 30

Free sample: S 030

S 030
S 071
S 101
S 131
S 151
S 191
S 212
S 282
S 334
S 353
S 515
S 525
S 606
S 616
S 656
S 676
S 747
S 757
All Cembrit product colours presented on the website are representative and might vary from the original product colours.
Colour Thickness Width Length
S 030 8 mm 1250 mm 3070 mm
S 030 8 mm 1280 mm 3080 mm
S 030 8 mm 1280 mm 2530 mm
S 030 8 mm 1250 mm 2500 mm
S 030 8 mm 1250 mm 2500 mm
S 030 8 mm 1250 mm 3050 mm
S 071 8 mm 1250 mm 3050 mm
S 071 8 mm 1250 mm 3050 mm
S 071 8 mm 1280 mm 2530 mm
S 071 8 mm 1280 mm 3080 mm
S 101 8 mm 1270 mm 3070 mm
S 101 8 mm 1280 mm 2530 mm
S 101 8 mm 1280 mm 3080 mm
S 131 8 mm 1280 mm 3080 mm
S 131 8 mm 1280 mm 2530 mm
S 151 8 mm 1250 mm 3050 mm
S 151 8 mm 1250 mm 2500 mm
S 191 8 mm 1250 mm 3050 mm
S 191 8 mm 1280 mm 2530 mm
S 191 8 mm 1280 mm 3080 mm
S 191 8 mm 1250 mm 2500 mm
S 212 8 mm 1192 mm 3050 mm
S 212 8 mm 1280 mm 3080 mm
S 212 8 mm 1280 mm 2530 mm
S 212 8 mm 1250 mm 2500 mm
S 212 8 mm 1270 mm 3070 mm
S 282 8 mm 1280 mm 3080 mm
S 282 8 mm 1280 mm 2530 mm
S 334 8 mm 1280 mm 2530 mm
S 334 8 mm 1280 mm 3080 mm
S 353 8 mm 1280 mm 2530 mm
S 353 8 mm 1280 mm 3080 mm
S 515 8 mm 1280 mm 2530 mm
S 515 8 mm 1280 mm 3080 mm
S 525 8 mm 1280 mm 2530 mm
S 525 8 mm 1250 mm 2500 mm
S 525 8 mm 1250 mm 3050 mm
S 606 8 mm 1280 mm 2530 mm
S 616 8 mm 1280 mm 2530 mm
S 616 8 mm 1250 mm 2530 mm
S 656 8 mm 1250 mm 3050 mm
S 656 8 mm 1280 mm 2530 mm
S 676 8 mm 1280 mm 2530 mm
S 676 8 mm 1280 mm 3080 mm
S 747 8 mm 1250 mm 2530 mm
S 747 8 mm 1250 mm 3070 mm
S 747 8 mm 1280 mm 2530 mm
S 757 8 mm 1280 mm 2530 mm
S 757 8 mm 1280 mm 3080 mm

Cembrit Solid

It will never let you down.

Cembrit Solid literally has you covered to the core. With this board, a word is a word. A colour is a colour. And solid means solid. It is the colourful edge to your building design and provides a calm expression from every angle thanks to its through-coloured qualities.

Small scratches and marks will remain practically invisible as the year's pass – maintaining its strong, but the subtle expression and living up to its name every single day.

Always beautiful. Always the same.

The special thing about Cembrit Solid boards is that they’re the same colour all the way through. Each of the core colours is matched with a full-coverage painted surface in vibrant yet resilient colours.

This means if you choose Cembrit Solid boards to provide a facade with a colour, every board will feature that colour on every surface and edge, and with the same colour on the edges of any cut-outs or drilled holes.

Cembrit Solid for decorative walls cladding is a strong and non-combustible sheet of fibre cement.

The boards have a cement grey core with a strong and durable surface treatment of water-based acrylic paint in strong colours. Learn more about how Cembrit Cover can be used in decorative interior wall cladding.

Product features:
NON COMBUSTIBLE
DURABLE
MAINTENANCE FREE
MOULD RESISTANT
IMPACT RESISTANT
SUSTAINABLE
THROUGH COLOURED

Technical data

Material

Fibre cement

Coating and surface

Water-based acrylic paint.

Type

Through coloured

Colours

18

Fire protection Class

A2 - s1, d0

Fixing - aluminium

For aluminium, substructure use Cembrit Rivets Aluminium 4.0x20mm. Make sure to use Cembrit Nose tool together with the rivet gun to get the correct tightening of the rivet.

Fixing - steel

For steel substructure use Cembrit Rivets steel 4.8x20mm or a Cembrit Facade screw CL-SS 4.8x29. A washer is pre-mounted on the screw to ensure the screw is centred and the hole is closed. Make sure to use Cembrit Nose tool together with the rivet gun to get the correct tightening of the rivet.

Fixing - wood

Cembrit Facade Screw is available as unpainted or in colours corresponding to the facade boards and in two steel qualities, A2 and A4. A washer is pre-mounted on the screw to ensure the screw is centred and the hole is closed.

References

Cembrit Solid

Selected colour: S 30

Installation

Cembrit Solid

Aluminum Installation

Aluminium support system Mounting 8mm Cembrit facade boards on aluminium Max. support distances: 629mm o.c. Max. rivet centres: 600mm Max wind load: Please refer to the wind load table for the correct distances for substructure and rivets. The following rivet types can be used for this construction: Cembrit Rivets Aluminium RIV-A 4.0x20mm  

Aluminium L Profile Detail

Cembrit facade boards can also be installed on horizontal aluminium systems. When using a horizontal support system, there must be a minimum of 20mm ventilated vertical area between the profiles and the supporting wall or insulation. 

Aluminum T Profile Joint

Edge Distances There should be a minimum of 20mm from the reverse of the facade board to the front face of the insulation to provide adequate ventilation. T profiles behind joints should be min 100mm width, and the L profiles should be min 40mm width. Joint gaps between boards should be min 8mm and max 16mm. The use of flat EPDM on aluminium profiles is optional, but from an aesthetic point of view, it may be advantageous to use it as the aluminium profiles will otherwise be visible through the joints. Alternatively, you can use black UV tape or painted aluminium profiles. 

Wood Installation

Installing 8mm Cembrit facade boards on timber frame Max support distances: 629mm o.c Max screw centres: 600mm o.c Max wind load: Please refer to the wind load table for the correct distances for substructure and screws. The following screws can be used for this solution: Cembrit Facade Wing Screw Wood, SCR-WW 4.9x38mm Cembrit Facade Screw Wood, SCR-W 4.5x30/36/41mm

Timber Screw Joint

Battens should be a minimum of 20mm thickness to provide adequate ventilation. Batten width should be minimum 100mm for supporting battens, and 45mm for central battens. Joint gaps between boards should be a minimum of 8mm and a maximum of 16mm. When using timber battens, always use Cembrit EPDM with profiled ribs.  

Cembrit recommends using an EPDM of the same width as the selected batten. Cembrit facade boards can also be installed on horizontal battens. When using horizontal substructures, there must be a minimum 20mm ventilated area behind the horizontal supporting battens. 

Steel Installation

To ensure the optimum, long term performance and aesthetic characteristics for Cembrit facade boards it is vital to ensure that the support system substructure is absolutely straight, horizontally and vertically. In order to ensure this, please follow the guidelines below. Straightness of substructure The horizontal tolerance is +/- 3.0mm measured over a distance of 2 meters The vertical tolerance is +/- 0.5mm over 600mm measured over a distance of 2 meters.

Top Hat Center

Edge Distances There should be a minimum of 20mm from the reverse of the facade board to the front face of the Windstopper or insulation to provide adequate ventilation. The profiles behind joints should be min 100mm width, and the middle profiles should be min 40mm width. Joint gaps between boards should be min 8mm and max 16mm. Always use flat EPTL/EPDM on steel profiles as it will provide adequate protection of the boards from moisture movements. From an aesthetic point of view, including the EPTL/EPDM will also make the steel profiles less visible through the joints.

Top Hat Center

Cembrit facade boards can also be installed on horizontal steel profile systems. When using a horizontal Cembrit VFL profile, the profiles can be mounted directly on the wall since it is perforated and the air can move freely. If using other horizontal systems, a minimum of 20mm ventilated vertical area between the profiles and the supporting wall or insulation must be ensured.