Aluminium support system Mounting 8mm Cembrit facade boards on aluminium Max. support distances: 629mm o.c. Max. rivet centres: 600mm Max wind load: Please refer to the wind load table for the correct distances for substructure and rivets. The following rivet types can be used for this construction: Cembrit Rivets Aluminium RIV-A 4.0x20mm
Colours & Measures
Cembrit Patina Original
Selected colour: P-020
Free sample: P-020



































Colour | Thickness | Width | Length |
---|---|---|---|
P-020 | 8 mm | 292 mm | 1192 mm |
P-020 | 8 mm | 1200 mm | 2500 mm |
P-020 | 8 mm | 1200 mm | 3050 mm |
P-020 | 8 mm | 1200 mm | 2500 mm |
P-020 | 8 mm | 1200 mm | 3050 mm |
P-020 | 8 mm | 592 mm | 2392 mm |
P-020 | 8 mm | 1250 mm | 2500 mm |
P-020 | 8 mm | 1250 mm | 3050 mm |
P-020 | 8 mm | 1192 mm | 2500 mm |
P-020 | 8 mm | 1250 mm | 2500 mm |
P-020 | 8 mm | 1250 mm | 3050 mm |
P-050 | 8 mm | 1200 mm | 2500 mm |
P-050 | 8 mm | 1200 mm | 3050 mm |
P-050 | 8 mm | 1200 mm | 2500 mm |
P-050 | 8 mm | 1200 mm | 3050 mm |
P-050 | 8 mm | 1250 mm | 2500 mm |
P-050 | 8 mm | 1250 mm | 3050 mm |
P-050 | 8 mm | 592 mm | 2392 mm |
P-070 | 8 mm | 1200 mm | 2500 mm |
P-070 | 8 mm | 1200 mm | 2500 mm |
P-070 | 8 mm | 1200 mm | 3050 mm |
P-070 | 8 mm | 1250 mm | 2500 mm |
P-070 | 8 mm | 1250 mm | 3050 mm |
P-070 | 8 mm | 292 mm | 1192 mm |
P-222 | 8 mm | 1200 mm | 2500 mm |
P-222 | 8 mm | 1200 mm | 3050 mm |
P-222 | 8 mm | 1200 mm | 2500 mm |
P-222 | 8 mm | 1200 mm | 3050 mm |
P-222 | 8 mm | 1250 mm | 2500 mm |
P-222 | 8 mm | 1250 mm | 3050 mm |
P-222 | 8 mm | 592 mm | 2392 mm |
P-222 | 8 mm | 292 mm | 1192 mm |
P-313 | 8 mm | 1200 mm | 2500 mm |
P-313 | 8 mm | 1200 mm | 3050 mm |
P-313 | 8 mm | 1250 mm | 2500 mm |
P-313 | 8 mm | 1250 mm | 3050 mm |
P-323 | 8 mm | 1250 mm | 2500 mm |
P-323 | 8 mm | 1250 mm | 3050 mm |
P-323 | 8 mm | 1200 mm | 2500 mm |
P-323 | 8 mm | 1200 mm | 3050 mm |
P-323 | 8 mm | 1250 mm | 2500 mm |
P-323 | 8 mm | 1250 mm | 3050 mm |
P-333 | 8 mm | 1200 mm | 2500 mm |
P-333 | 8 mm | 1200 mm | 3050 mm |
P-333 | 8 mm | 1250 mm | 2500 mm |
P-333 | 8 mm | 1250 mm | 3050 mm |
P-343 | 8 mm | 1250 mm | 2500 mm |
P-343 | 8 mm | 1250 mm | 3050 mm |
P-343 | 8 mm | 1200 mm | 2500 mm |
P-343 | 8 mm | 1200 mm | 3050 mm |
P-343 | 8 mm | 1250 mm | 2500 mm |
P-343 | 8 mm | 1250 mm | 3050 mm |
P-545 | 8 mm | 1200 mm | 2500 mm |
P-545 | 8 mm | 1200 mm | 3050 mm |
P-545 | 8 mm | 1250 mm | 2500 mm |
P-545 | 8 mm | 1250 mm | 3050 mm |
P-565 | 8 mm | 1200 mm | 3050 mm |
P-565 | 8 mm | 1200 mm | 2500 mm |
P-565 | 8 mm | 1250 mm | 3050 mm |
P-565 | 8 mm | 1250 mm | 2500 mm |
P-565 | 8 mm | 1200 mm | 3050 mm |
P-626 | 8 mm | 1200 mm | 3050 mm |
P-626 | 8 mm | 1200 mm | 2500 mm |
P-626 | 8 mm | 1192 mm | 3050 mm |
P-626 | 8 mm | 1250 mm | 2500 mm |
P-626 | 8 mm | 1250 mm | 3050 mm |
P-626 | 8 mm | 1250 mm | 2500 mm |
P-626 | 8 mm | 1250 mm | 3050 mm |
Cembrit Patina Original
Anything but ordinary
Cembrit Patina Original has fine, sanding lines on the surface. Here’s a façade board that may be standard, yet it is much more than ordinary.
Cembrit Patina Original comes in timeless colours – it evolves and changes the expression of your building. These façade boards will patinate beautifully over time, adding an aesthetic look to the building design with some unique and subtle variations on the surface.
Cembrit Patina Original connects performance with a modern, versatile look. At a time, when everyone is searching for authenticity and natural look, Cembrit Patina Original is the perfect choice for your building.
Special product characteristics:
- Natural and authentic look
- Fine sanding lines on the surface
- Patination enhances the individual expression of your building
- Virtually maintenance-free
Cembrit Patina Original multi-purpose facade boards can also be used for interior applications as a decorative wall cladding solution.
The Cembrit Patina facade boards are ideal for interior purposes due to their moisture-resistant and mould-resistant properties. Read more to find out how Cembrit Patina Original boards can be used for decorative wall cladding
Product features:








Technical data
Coating and surface
Cembrit Patina’s manufacturing process gives the boards a unique surface texture and with a hydrophobic surface.
Colours
11
Fire protection Class
A2 - s1, d0
Fixing - steel
For steel substructure use Cembrit Rivets steel 4.8x20mm or a Cembrit Facade screw CL-SS 4.8x29. Make sure to use Cembrit Nose tool together with the rivet gun to get the correct tightening of the rivet.
Fixing - wood
Cembrit Facade Screw is available as unpainted or in colours corresponding to the facade boards and in two steel qualities, A2 and A4
Material
Fibre cement
Type
Through coloured
Certificates
Downloads
Cembrit Patina Original
References
Cembrit Patina Original
Selected colour: P-020
Installation
Cembrit Patina Original
Aluminum Installation

Aluminum T Profile Center

Aluminum L Profile Center
Edge Distances There should be a minimum of 20mm from the reverse of the facade board to the front face of the insulation to provide adequate ventilation. T profiles behind joints should be min 100mm width, and the L profiles should be min 40mm width. Joint gaps between boards should be min 8mm and max 16mm. The use of flat EPDM on aluminium profiles is optional, but from an aesthetic point of view, it may be advantageous to use it as the aluminium profiles will otherwise be visible through the joints. Alternatively, you can use black UV tape or painted aluminium profiles

Cembrit facade boards can also be installed on horizontal aluminium systems. When using a horizontal support system, there must be a minimum of 20mm ventilated vertical area between the profiles and the supporting wall or insulation.
Wood Installation

Installing 8mm Cembrit facade boards on timber frame Max support distances: 629mm o.c Max screw centres: 600mm o.c Max wind load: Please refer to the wind load table for the correct distances for substructure and screws. The following screws can be used for this solution: Cembrit Facade Wing Screw Wood, SCR-WW 4.9x38mm Cembrit Facade Screw Wood, SCR-W 4.5x30/36/41mm
Timber Screw Joint

Battens should be a minimum of 20mm thickness to provide adequate ventilation. Batten width should be minimum 100mm for supporting battens, and 45mm for central battens. Joint gaps between boards should be a minimum of 8mm and a maximum of 16mm. When using timber battens, always use Cembrit EPDM with profiled ribs.
Timber Screw Center

Cembrit recommends using an EPDM of the same width as the selected batten. Cembrit facade boards can also be installed on horizontal battens. When using horizontal substructures, there must be a minimum 20mm ventilated area behind the horizontal supporting battens.
Steel Installation

To ensure the optimum, long term performance and aesthetic characteristics for Cembrit facade boards it is vital to ensure that the support system substructure is absolutely straight, horizontally and vertically. In order to ensure this, please follow the guidelines below. Straightness of substructure The horizontal tolerance is +/- 3.0mm measured over a distance of 2 meters The vertical tolerance is +/- 0.5mm over 600mm measured over a distance of 2 meters.
Top Hat Center

Edge Distances There should be a minimum of 20mm from the reverse of the facade board to the front face of the Windstopper or insulation to provide adequate ventilation. The profiles behind joints should be min 100mm width, and the middle profiles should be min 40mm width. Joint gaps between boards should be min 8mm and max 16mm. Always use flat EPTL/EPDM on steel profiles as it will provide adequate protection of the boards from moisture movements. From an aesthetic point of view, including the EPTL/EPDM will also make the steel profiles less visible through the joints.
Top Hat Center

Cembrit facade boards can also be installed on horizontal steel profile systems. When using a horizontal Cembrit VFL profile, the profiles can be mounted directly on the wall since it is perforated and the air can move freely. If using other horizontal systems, a minimum of 20mm ventilated vertical area between the profiles and the supporting wall or insulation must be ensured